diabatic cooling is a process based on the evaporation of moisture. As a result, energy is extracted from the air and the temperature drops. HomEvap uses this process to cool indirectly in a very energy-efficient and sustainable way. As a result, the humidity in the room is not increased in the summer
The HomEvap Cooler can be connected to any heat recovery unit with a maximum of 800m3/h air volume.
No aerosols (very small suspended droplets) are produced, so there is no risk of legionella. No water is circulated either.
The water consumption is a maximum of 5 l/h. When you use the HomEvap 24 hours a day for 4 months, the water consumption is 14 m3 on an annual basis. The price of water in the Netherlands varies between € 0.84 and € 1.66 per m3, so the costs are a maximum of € 23.24.
During cooling, the maximum electricity consumption is 10 watts per operating hour.
The HomEvap is connected to the water supply and is therefore automatically filled.
This depends on the type of water you have. With hard water, we recommend installing a reverse osmosis filter on the water supply. It is advisable to have the installer carry out a check once a year. With normal use and proper installation, the matrix should be replaced once every two years. We recommend a Nanofilter for poor quality water.
Air resistance in Pascal (PA) |
|
||||||||
100 |
200 |
275 |
350 |
500 |
600 |
700 |
m3/h |
|
|
7 |
15 |
24 |
38 |
63 |
86 |
RESISTANCE IN HUMIDIFIER |
|||
3 |
6 |
9 |
14 |
25 |
38 |
46 |
RESISTANCE IN COOLER |
||
PASCAL |
|
Take the manual from the control panel. On page 3 there is an overview of the messages and the action that must be taken. If you no longer have a manual, it can also be downloaded from the website under support.